Household » Others » Logicstop Plus Pump Motor Protection Control Household » Others » Logicstop Plus Pump Motor Protection Control Household » Others » Logicstop Plus Pump Motor Protection Control

Household » Others » Logicstop Plus Pump Motor Protection Control
English Deutsch Italian French Español Português Русский  Choose your
language
Расширенный поиск
Cart Корзина
Вы еще ничего не заказали!
  Предложения
  Поиск
  Написать
  Регистрация
  Вход
КАТАЛОГ
        Antique, Art
        Car
        DVD Movies
        Electronics
        Fashion
        Game
        Gift
        Green Power
        Health & Beauty
        Hello Kitty
        Household
          - Energy Saver
          - Others
          - Special small machines
        Hungaricum
        Interior Design
        Navigation (GPS)
        Party Supplies, Decorations
        Phones
        Retro
        Software
        Sport
        Spy & Security Technics
        Tablets
        Travel
        Watch
        Аппаратное обеспечение
ПОСТАВЩИК
 
Household » Others
Logicstop Plus Pump Motor Protection Control
Увеличить
Logicstop Plus Pump Motor Protection Control
[LOGICSTOPPLUS]
Item #:  278
Logicstop Plus for electronic pump saver:
  • Stops the pump in case of a water shortage and protects it from dry running.
  • Stops the pump and protects the motor in case of overcurrent.

Installation and startup

To operate, it must be connected to the power supply line of the pump.
For this reason, the power supply of the pump must be inserted in the device, which is then connected to the power point.
In case of water shortage, the device stops the pump protecting it from dry running. This failure is indicated with the blinking red (Failure) LED.
In case of the current absorption exceeding 10 Ampere, the device stops the pump motorand protects it against overcurrent. This failure is indicated with the red (Failure) LED on.
To restore normal operation to the device and the system simply press the red (Restart) button.
In case of a temporary blackout, the device will automatically rearm once the electricity returns.

Control Panel

Signaling of the working phases and anomalies
  • Green LED (Power on): on - Device energized
  • Yellow LED (Pump on): on - Pump running
  • Red LED (Failure):
    • blinking - Water shortage
    • on - Overcurrent
  • Red Button (Restart): Motor data acquisition or Reset after failure

Technical features

  • Single-phase mains voltage: 230 VAC
  • Acceptable voltage fluctuation: ±10 %
  • Frequency: 50 Hz
  • Current: min 6 A - max 10 A
  • Ambient temperature: max 55 °C